Hail Size Chart: Roof Damage Thresholds by Material
The definitive reference for what size hail damages each roofing material — with UL 2218 class ratings, real impact test data, and a color-coded damage matrix across 9 material types.
In This Guide
- Hail Size Reference Chart (Diameter, Velocity & Energy)
- Material Damage Matrix — Color-Coded by Hail Size
- UL 2218 Class 1–4 Impact Ratings Explained
- GAF Shingle Performance by Hail Size
- Material-by-Material Damage Breakdown
- Why North Alabama Gets Hit Hard
- When to File a Claim vs. When Damage Is Cosmetic
- How Ridgeline Inspects for Hail Damage
- Frequently Asked Questions
Most homeowners know hail is bad for roofs. But few know there are precise, tested thresholds for exactly when each material starts taking damage — and those thresholds vary dramatically by material type.
A 1-inch hailstone can destroy an aged 3-tab asphalt shingle while leaving a slate roof completely intact. A 2-inch hailstone that punches through standard architectural shingles may cause only cosmetic denting on a standing seam metal roof. Understanding these thresholds is the difference between a smart material decision and a costly one.
This guide compiles data from Haag Engineering Co.’s ice-ball impact studies (published with the American Meteorological Society), UL 2218 test specifications, manufacturer specifications including GAF’s product documentation, and Sheffield Metals’ technical research. The damage thresholds below are based on scientific testing — not estimates.
1. Hail Size Reference Chart
Hail is measured by diameter and commonly described using everyday objects as reference points. The chart below shows each benchmark size at true relative scale, color-coded by damage severity zone. Scroll down for the full data table with velocity and kinetic energy figures derived from Greenfeld (1969) — National Bureau of Standards — and replicated in Haag Engineering Co.’s published AMS research.
Full data table with velocity and kinetic energy:
| Common Name | Diameter (in.) | Diameter (cm) | Approx. Weight | Terminal Velocity | Impact Energy | NWS Severity |
|---|---|---|---|---|---|---|
| Pea | 0.25″ | 0.6 cm | ~0.003 oz | ~27 mph | <0.1 ft-lb | Not severe |
| Mothball | 0.50″ | 1.3 cm | ~0.02 oz | ~34 mph | ~0.1 ft-lb | Not severe |
| Marble / Dime | 0.75″ | 1.9 cm | ~0.04 oz | ~42 mph | 0.44 ft-lb | Not severe |
| Penny | 0.88″ | 2.2 cm | ~0.06 oz | ~46 mph | ~0.7 ft-lb | Approaching |
| Quarter | 1.00″ | 2.5 cm | ~0.1 oz | ~50 mph | 1.43 ft-lb | Severe threshold |
| Half Dollar | 1.25″ | 3.2 cm | ~0.19 oz | ~56 mph | 3.53 ft-lb | Severe |
| Walnut / Ping-Pong | 1.50″ | 3.8 cm | ~0.33 oz | ~61 mph | 7.35 ft-lb | Severe |
| Golf Ball | 1.75″ | 4.5 cm | ~0.56 oz | ~66 mph | 13.56 ft-lb | Very Severe |
| Hen Egg | 2.00″ | 5.1 cm | ~0.84 oz | ~72 mph | 23.71 ft-lb | Destructive |
| Tennis Ball | 2.50″ | 6.4 cm | ~1.5 oz | ~80 mph | 57.48 ft-lb | Destructive |
| Baseball | 2.75″ | 7.0 cm | ~2.1 oz | ~84 mph | ~81 ft-lb | Catastrophic |
| Softball | 4.00″ | 10.2 cm | ~5.0 oz | ~95 mph | ~200+ ft-lb | Catastrophic |
The 1-inch rule: The National Weather Service defines severe thunderstorms partly on hail size. Their severe threshold was recently revised upward to 1 inch — precisely because Haag Engineering’s research showed that 1″ is when widespread roof damage begins across the most common residential materials.
2. Material Damage Matrix
The heatmap below crosses hail size (rows) against 9 roofing material types (columns). Each cell is color-coded green through red by expected damage outcome, based on Haag Engineering ice-ball impact studies, UL 2218 test data, manufacturer specifications, and field inspection reports. All values assume perpendicular impact at terminal velocity on properly installed, code-compliant roofing in normal condition.
Aged, weathered materials will begin sustaining damage at smaller sizes. Extreme hail angles, wind-driven hail, or already-deteriorated materials may shift outcomes one step worse.
Select your roof material to see how it handles each hail size:
Compare two materials side by side to see where performance diverges:
| Hail Size | Material A | Material B |
|---|
Color-coded data table (accessible text version):
| Hail Size | 3-Tab Asphalt | Architectural (HDZ) | Class 4 IR (AS II) | Standing Seam Metal | Corrugated Metal | Clay Tile | Concrete Tile | Natural Slate (¼”) | Wood Shake |
|---|---|---|---|---|---|---|---|---|---|
| 0.75″ (Marble) | No Damage | No Damage | No Damage | No Damage | No Damage | No Damage | No Damage | No Damage | No Damage |
| 1.00″ (Quarter) | Functional* | No Damage | No Damage | No Damage | Cosmetic | No Damage | No Damage | No Damage | No Damage |
| 1.25″ (Half Dollar) | Functional | Cosmetic | No Damage | Cosmetic (thin) | Cosmetic | No Damage | Cosmetic (corners) | No Damage | Cosmetic |
| 1.50″ (Walnut) | Severe | Functional | No Damage | Cosmetic | Functional | Functional (corners) | Functional (some) | No Damage | Functional |
| 1.75″ (Golf Ball) | Severe | Severe | Cosmetic | Cosmetic | Functional | Functional | Functional | Cosmetic (¼” thick) | Severe |
| 2.00″ (Hen Egg) | Severe | Severe | Cosmetic | Cosmetic–Functional | Functional | Severe | Severe | Cosmetic (⅜” thick) | Severe |
| 2.50″ (Tennis Ball) | Severe | Severe | Functional | Functional (dents/seams) | Severe | Severe | Severe | Functional | Severe |
| 2.75″+ (Baseball+) | Severe | Severe | Severe | Severe | Severe | Severe | Severe | Severe | Severe |
3. UL 2218 Class 1–4 Impact Ratings Explained
UL 2218 — “Standard for Impact Resistance of Prepared Roof Covering Materials” — is the industry benchmark for classifying how well a roofing product resists impact. It was developed by Underwriters Laboratories and is the rating system used by most state insurance regulators, including Alabama and Florida, to qualify products for premium discounts.
The test drops a steel ball twice on the same spot from a specified height. If the material doesn’t crack, tear, or split through to the backing after two identical hits, it passes at that class level. Testing locations include the most vulnerable spots: edges, corners, overlaps, and unsupported mid-panel areas.
Full specification table:
| UL 2218 Class | Steel Ball Diameter | Drop Height | Impact Energy | Real-World Hail Equivalent | What It Means |
|---|---|---|---|---|---|
| Class 1 | 1.25 inches | 12 feet | 3.53 ft-lbs | ~1.25″ hail / Half Dollar | Minimum impact resistance. Covers light hail events. Most standard 3-tab shingles do not pass even this class. |
| Class 2 | 1.50 inches | 15 feet | 7.35 ft-lbs | ~1.5″ hail / Walnut size | Moderate impact resistance. Covers common hail events. Many entry-level architectural shingles fall here. |
| Class 3 | 1.75 inches | 17 feet | 13.56 ft-lbs | ~1.75″ hail / Golf Ball | Good impact resistance. GAF Timberline HDZ achieves Class 3. Qualifies for insurance discounts in many states. |
| Class 4 | 2.00 inches | 20 feet | 23.71 ft-lbs | ~2″ hail / Hen Egg | Highest rating. GAF ArmorShield II, Timberline UHDZ with UltraMat. Qualifies for maximum insurance discounts. Required by some AL/FL insurers for full replacement coverage. |
Important limitation: A Class 4 rating means a material passed the UL 2218 test — it is not a warranty against hail damage. Extremely large hail (2.5″ and above), wind-driven hail at non-perpendicular angles, or multiple strikes in the same location can still cause damage to Class 4 materials. No roofing product is hail-proof.
Who Recognizes UL 2218 Class 4?
Alabama does not have a statewide mandate, but many private insurers operating in Alabama and Florida offer discounts for Class 4 roofing — typically 5–15% off the wind and hail portion of your premium. In coastal Alabama counties (Baldwin and Mobile), FORTIFIED certification combined with Class 4 shingles can produce premium reductions of 25–55% depending on your insurer and coverage tier. Alabama homeowners already pay among the highest premiums in the nation — an average of $4,123 per year in 2024 (MoneyGeek), which is $1,700 above the national average.
4. GAF Shingle Performance by Hail Size
As a GAF President’s Club contractor — a distinction held by fewer than 1% of roofing contractors nationwide — Ridgeline installs the full GAF shingle lineup and can speak with authority on how these products perform in real Alabama hailstorms.
Use the interactive comparison tool above (Section 2) to compare all three GAF tiers side by side: select “3-Tab Shingles” as Material A and “Class 4 (ArmorShield II)” as Material B to see the performance gap at each hail threshold. The distinctions matter enormously in North Alabama, where the Tennessee Valley produces hailstorms averaging 1.46 inches in reported diameter.
Full GAF product comparison table:
| Hail Size | Standard 3-Tab (e.g., GAF Royal Sovereign) | Timberline HDZ (Class 3 — most popular) | ArmorShield II / UHDZ (Class 4 — SBS-modified) |
|---|---|---|---|
| 0.75″ (Marble) | No Damage | No Damage | No Damage |
| 1.00″ (Quarter) | Functional damage likely on aged shingles; granule displacement, mat exposure | No Damage — additional laminate layers and fiberglass mat provide buffer | No Damage — SBS-modified rubberized asphalt absorbs impact energy |
| 1.25″ (Half Dollar) | Severe — widespread bruising, loss of waterproofing integrity likely | Cosmetic — some granule loss possible; no structural compromise | No Damage — passes UL 2218 Class 4 test at this energy level |
| 1.50″ (Walnut) | Severe — replacement typically needed | Functional — significant granule displacement, potential mat fracture | No Damage — Class 4 rated, well within test threshold |
| 1.75″ (Golf Ball) | Severe | Severe — exceeds Class 3 test threshold (1.75″ test ball) | Cosmetic — possible surface marks; function maintained; Class 4 passes at this size |
| 2.00″ (Hen Egg) | Severe | Severe | Cosmetic to Functional — at the Class 4 test threshold; some impacts may cause granule displacement |
| 2.50″+ (Tennis Ball+) | Severe | Severe | Severe — exceeds all UL 2218 test parameters; replacement needed |
Why SBS Modification Matters
Standard asphalt shingles behave like brittle plastic at the moment of hail impact — they either absorb the blow or fracture. GAF ArmorShield II uses SBS-modified asphalt, which contains a rubber polymer that gives the material elasticity. Instead of cracking under a 2-inch impact, the modified asphalt deforms slightly and springs back, preventing mat fracture. This is the same technology used in high-performance commercial roofing membranes.
The Timberline HDZ does not use SBS modification — it achieves its Class 3 rating through its dual-layer laminated construction and heavier overall weight. Both are legitimate approaches to impact resistance, but for homeowners in hail-prone areas like North Alabama, the SBS difference often means the gap between a no-claim outcome and a $15,000–$25,000 insurance claim.
5. Material-by-Material Damage Breakdown
3-Tab Asphalt Shingles
Three-tab shingles are the most vulnerable common roofing material to hail. The single-layer construction, lower overall weight, and standard asphalt composition provide minimal energy absorption at impact. Haag Engineering’s ice-ball tests found that aged organic-mat 3-tab shingles began sustaining damage at 50% of impacts with 1-inch stones. Fiberglass-mat versions were more resilient, reaching 60% damage rates at 1.25 inches.
The critical word is “functional damage” — defined in the roofing industry as a diminution of water-shedding capability or reduction in expected long-term service life (Morrison, 1999). Quarter-sized hail doesn’t necessarily punch a hole through a 3-tab shingle immediately, but it displaces granules, exposes the underlying bitumen to UV degradation, and accelerates aging by years. The roof may not leak today, but its remaining service life is significantly shortened.
Architectural / Dimensional Shingles (Timberline HDZ)
Architectural shingles outperform 3-tab significantly due to their laminated construction. Haag Engineering’s 2002 test data showed that 30-year laminated shingles showed 0% damage at 1.25 inches and 60% damage at 1.5 inches — a full quarter-inch advantage over 3-tab products. The dual-layer construction distributes impact energy across a larger surface area rather than concentrating it at a single point.
The GAF Timberline HDZ achieves UL 2218 Class 3, meaning it withstands a 1.75-inch steel ball dropped from 17 feet twice on the same spot. In practical terms, this means golf-ball-sized hail is approaching the threshold where functional damage can occur. For North Alabama — where the March 2, 2012 storm produced average hail of 1.46 inches across 500+ reports — an HDZ roof in that storm would likely show cosmetic damage but maintain waterproofing integrity.
Class 4 Impact-Resistant Shingles (GAF ArmorShield II)
Class 4 shingles represent the highest UL 2218 rating available for asphalt products. GAF ArmorShield II uses SBS-modified asphalt and passes a 2-inch steel ball drop from 20 feet — 23.71 foot-pounds of impact energy — twice on the same spot without fracturing the mat or splitting the material. That 2-inch threshold corresponds roughly to a hen-egg-sized hailstone at terminal velocity.
In Alabama and coastal Florida, Class 4 shingles can qualify for insurance premium discounts of 5–15% from most carriers, and up to 25–55% when combined with FORTIFIED certification. GAF’s full Class 4 lineup for North Alabama includes: ArmorShield II (SBS-modified, 130 mph wind rating), Timberline UHDZ with UltraMat (Class 4, WindProven unlimited speed warranty, nationwide availability since February 2026), and Grand Sequoia AS (Class 4, wood shake aesthetic).
Metal Roofing
Metal roofing presents a unique damage profile: it typically does not fail structurally from hail, but it can sustain cosmetic denting that affects appearance and resale value. The distinction between denting and puncturing is critical.
Denting occurs when a hailstone deforms the metal surface without compromising the paint system or substrate integrity — a cosmetic issue with no functional consequence. Puncturing, where the hailstone actually breaches the metal, is rare and requires extremely large hailstones or extremely thin gauge material. Standing seam metal with 24-gauge steel panels and integrated striation patterns showed no significant denting from 1-inch hail and cosmetic denting only from 1.25–1.75 inch hail in Sheffield Metals’ technical research.
Thinner 29-gauge panels are meaningfully more susceptible to denting than 22- or 24-gauge panels. Flat panels show dents more visibly than panels with striations, bead ribs, or pencil ribs. If you choose metal roofing in a hail zone, specify at minimum 24-gauge steel with panel striations. Sheffield Metals’ sheet and coil material carries a Class 4 UL 2218 rating.
One important nuance: many insurers offer metal roofing a “cosmetic damage waiver” — you can exclude cosmetic hail damage from coverage in exchange for a lower premium. This is worth discussing with your agent before signing, particularly if your metal roof involved significant investment.
Clay and Concrete Tile
Tile roofing is counterintuitive in hail situations. Because tile is hard and relatively brittle, it can crack or shatter on direct impact — but it also can be highly resistant because hailstones themselves tend to shatter on impact with hard surfaces.
Haag Engineering’s 2004 AMS paper on tile damage found that no concrete tile was fractured by 1-inch ice balls, even in the most vulnerable locations. Of 13 concrete tile products tested, four fractured at corners with 1.25-inch balls, and six remained unbroken at 1.5 inches. All 13 fractured with 2.5-inch balls.
Clay tile testing found no fractures at 1.25 inches, with corner fractures beginning at 1.5 inches. The field areas of tiles are significantly more impact-resistant than edges and corners. A critical warning for tile inspections: curved corner fractures are extremely common in concrete tile from thermal expansion, improper installation, or foot traffic, and are frequently misidentified as hail damage. Hail fractures typically radiate from the impact point; thermal fractures run along tile edges.
Slate
Natural slate is among the most impact-resistant roofing materials available. FM 4473 testing on behalf of the National Slate Association found that quarter-inch-thick natural slate (North Country Slate’s Unfading Black) sustained no cracking from 1.75-inch ice balls fired at approximately 100 feet per second — earning a Class 3 rating. Three-eighth-inch-thick slate withstood 2-inch ice balls with no damage, achieving Class 4. That said, slate struck directly by 2.5-inch or larger hailstones at high velocity can crack, particularly on thinner tiles or at edges and overlaps.
Synthetic slate products vary dramatically. Rubber-based synthetic slates from established manufacturers may achieve Class 4. Cheaper polymer synthetics may not be independently tested. Always verify UL 2218 certification for any synthetic slate product.
Wood Shakes
Cedar shakes occupy the middle tier of impact resistance. Haag Engineering tests found cedar shingles beginning to sustain hairline fractures at 1.25 inches, while heavy cedar shakes showed 50% damage rates at 1.5 inches. By 1.75 inches, 90% of heavy cedar shake test panels showed damage. Fractures in wood shakes from hail are characterized by uniform cleavage through the wood grain and unweathered interior surfaces — distinct from checking (age cracking) and splitting from installation.
Wood shakes are uncommon in new construction in Alabama due to Class A fire rating requirements and local codes. However, many existing homes in established neighborhoods of Huntsville, Athens, Madison, and Decatur still have original shake roofs that should be inspected after any hail event of 1.25 inches or more.
6. Why North Alabama Gets Hit Hard
North Alabama sits at the convergence of two atmospheric conditions that routinely produce severe hail: warm, moisture-laden air flowing north from the Gulf of Mexico, and cold, dry air moving southeast off the Great Plains. When these air masses collide over the Tennessee Valley, they generate intense supercell thunderstorms capable of supporting large hail.
The Tennessee Valley’s topography — the valley itself flanked by the Cumberland Plateau to the northeast and the foothills of the Appalachians — can create atmospheric lift that intensifies thunderstorm development. Areas like Huntsville, Athens, Decatur, and Madison County sit squarely in this convergence zone.
The National Weather Service tracks hail frequency across the Southeast. Northern Alabama — including Madison County (Huntsville), Limestone County (Athens), and Morgan County (Decatur) — reports among the highest hail-event frequencies in the state, with higher rates than coastal areas. These areas see not just more hail events, but hail from longer-track supercells that sustain large stones at height for extended periods.
North Alabama homeowners face a structural disadvantage compared to, say, Denver or Dallas: the region has historically underinvested in impact-resistant materials because hail has not always been the cultural focus that it is in the Great Plains. The result is a significant inventory of 3-tab and older architectural shingle roofs that face repeated hail events with inadequate protection — and homeowners who discover the damage only when staining appears on interior ceilings months later.
Ridgeline’s Perspective on North Alabama Hail Risk
Since founding in 2012, we’ve replaced thousands of roofs across Huntsville, Athens, Madison, Decatur, and surrounding communities following hail events. The pattern is consistent: standard architectural shingle roofs from hailstorms averaging 1.25–1.5 inches show widespread granule loss and accelerated aging that insurers consider claimable functional damage. Homeowners who upgraded to Class 4 materials during prior replacement cycles rarely need a full replacement — they may have cosmetic marks, but their roofs are intact and watertight.
We recommend Class 4 impact-resistant shingles for any re-roof in the North Alabama market, and we price them competitively. The insurance savings alone — often $400–800/year in premium reduction — can offset the material upgrade cost within 5–7 years.
7. When to File a Claim vs. When Damage Is Cosmetic Only
The distinction between functional and cosmetic damage is the central question in any post-hail insurance claim — and it is frequently contested. Here is the framework used by professional roofing inspectors and insurance adjusters to make that determination.
Functional Damage (File a Claim)
- Mat fractures or tears visible on asphalt shingles — the fiberglass or organic mat beneath the granules is cracked or punctured
- Exposed bitumen — granules stripped to reveal the black asphalt layer beneath
- Soft spots or bruises on shingles — pressing reveals the mat has been fractured beneath the surface
- Cracked, broken, or shattered tile
- Wood shake fractures that open under water flow (not hairline surface checks)
- Metal panel paint cracking or substrate perforation
- Damaged flashing, vents, gutters, or pipe collars that affect water management
Cosmetic Damage (May Not Be Claimable)
- Granule marks on shingles where the mat is intact and bitumen is not exposed
- Surface denting on metal panels with no paint cracking or perforation
- Spatter marks on tile that involve no fracture
- Superficial surface scuffing on synthetic materials
Alabama homeowner alert: Many Alabama insurers now include cosmetic exclusion clauses in standard policies — particularly for metal roofing. Read your policy carefully before a storm, not after. If your policy excludes cosmetic damage, a hail event that dents your metal roof without perforating it may not be a covered loss. Ask your agent specifically about cosmetic exclusions on your renewal.
What Hit My Roof? Quick Assessment
Tell us the hail size and your roof material for an instant damage estimate.
The Hail Size Threshold for Claims
Alabama insurance adjusters and roofing consultants generally use 1 inch as the minimum hail size that can produce claimable functional damage on a standard asphalt shingle roof. Below 1 inch, damage is typically limited to surface granule displacement without functional compromise. Above 1 inch, an inspection is warranted regardless of whether damage is visually obvious from the ground.
For Class 4 shingles, the practical claim threshold rises to approximately 2 inches — events that exceed the UL 2218 test parameters. For clay or concrete tile, claimable fracture damage begins appearing at 1.5–1.75 inches in field conditions.
One important note: the size of hail that fell on your street is not always what matters. Hail size within a single storm cell can vary by half an inch over a few hundred feet. Professional documentation of hail size — through storm reports, spotter data, or physical evidence like dents in aluminum gutters and downspouts (which dent at known sizes) — is essential for claim support.
8. How Ridgeline Inspects for Hail Damage
As a GAF President’s Club contractor and BBB Torch Award for Ethics recipient (North Alabama, 2023), Ridgeline brings structured inspection methodology to every post-storm assessment. Our inspections follow the protocol established by the roofing industry for hail damage documentation and are conducted by trained professionals who understand the difference between hail damage, aging, and installation defects.
What We Look At
- Soft metals first: Aluminum gutters, downspouts, HVAC flashing caps, and AC condenser fins dent predictably at known hail sizes. A dented aluminum gutter cap tells us approximately what size hail hit the property and confirms a storm event occurred — essential for insurance documentation.
- Test squares: We examine representative 10-square-foot sections across multiple roof planes, counting and mapping impact marks per unit area. Density of impacts matters as much as severity — adjusters look for a random distribution of marks consistent with hail pattern.
- Shingle face inspection: We identify true hail strikes (round, random impact marks with granule displacement in a circular pattern) vs. blistering (round bubbles from manufacturing defects) vs. mechanical damage from foot traffic.
- Mat integrity check: Gentle thumb pressure at suspected impact sites reveals whether the mat beneath has been fractured. A bruised shingle has a soft, spongy feel at the impact point — a healthy shingle does not.
- Flashing and penetrations: Ridge caps, pipe boots, valley metal, and skylights often sustain the most visible damage and are examined carefully.
- Interior attic inspection: We check for daylight through decking, water staining on sheathing, and premature aging of the underlayment — signs that functional damage has progressed beyond the shingle surface.
What You Get
After a Ridgeline inspection, you receive a documented assessment of what we found, which materials show damage, and whether the damage meets the threshold for an insurance claim. We do not pressure-sell — if your roof is fine, we tell you. If damage is present, we help you understand the claim process and can work directly with your adjuster. Ridgeline inspections are free for homeowners across our 31 North Alabama, Gulf Coast Alabama, and Florida Panhandle service cities.
Free Post-Storm Inspection — Results in 24 Hours
After any hail event of 1 inch or larger, call us. We’ll put a trained inspector on your roof within 24 hours and give you a written assessment. No obligation. We serve 31 cities across North Alabama, Gulf Coast Alabama, and the Florida Panhandle from offices in Athens/Huntsville, Spanish Fort, and Pensacola.
- North Alabama (Athens/Huntsville): (256) 325-1345
- Gulf Coast Alabama (Spanish Fort): (251) 307-5512
- Florida Panhandle (Pensacola): (850) 226-5279
About Ridgeline Construction
Ridgeline Construction has been a family-owned roofing contractor in North Alabama and the Gulf Coast since 2012. Founded by Lauren and Terry Marsh, Ridgeline holds GAF Master Elite and President’s Club certifications (top 1% of contractors nationwide), the BBB Torch Award for Ethics (North Alabama, 2023), and has completed 10,000+ roofs across Alabama and Florida. As a GAF Master Elite contractor, Ridgeline can offer the GAF Golden Pledge warranty — lifetime limited manufacturing-defect coverage with 50 non-prorated years for qualifying individual-owned detached homes with lifetime limited workmanship coverage for qualifying individual-owned detached homes, including 25 or 30 non-prorated years depending on the eligible shingles, backed directly by GAF. Research in this article draws on Haag Engineering Co. published studies, UL 2218 technical specifications, GAF manufacturer documentation, Sheffield Metals technical research, and North Country Slate FM 4473 test data. Material thresholds represent general industry findings; individual results vary by material age, installation quality, wind angle, and hail density.
Frequently Asked Questions
Get Your Free Estimate
Schedule a free inspection with a GAF-certified expert. No obligation.